BESST INC HOME
Home  |  Product SOPS  |  Article of Interest | Experiences |  Contact Us


MondoProbe
Simultaneous Collection of Soil Core and Soil-Gas Or Simultaneous Collection of Soil Core and Groundwater
MondoProbe
(Click here to enlarge MondoProbe)
MondoProbe Specifications:
Length = 4 feet (1.2 m)
Maximum Outside Diameter = 4-Inches (100 mm)
Screen Dimensions = 4-Inches L x 3-Inches OD
Core Dimensions = 2.5-Inch OD x 17 L
Water Canister Volume = 2 Liters
Water Canisters Can Be Stacked
Sample Discharge = Drain From Bottom after removed from core barrel section.
Pressurization = Typically Nitrogen gas or with air compressor. Top Connection = NW)
Application = Simultaneous Soil and Groundwater or Soil and Soil Gas Depth Discrete Sampling.
Rig Compatibility = Hollow Stem Auger, Air Rotary Casing Hammer (ARCH), Dual Wall Percussion (Becker Rig), Mud or Air Rotary, Sonic
Drive Method = Air or Hydraulic Pile Drive (Up to 10,000 Lb. Strike Weight).
Durability = Heavy wall construction. Parts wear out slowly over several hundred drive events with 10 to 500 blows per event.
MondoProbe (PDF Downloads)
Written SG SOPs (178k)
Written GW SOPs (213k)
Vacuum Box SOPs (128k)
Illustrated SOPs (257k)
Assembly Diagrams (527k)
Giant H2vape
H2Vape: Water Sampling
(Click here to enlarge H2vape)
Giant H2Vape Specifications:
Length = 5 feet (1.5 m) in closed position
Shaft Outside Diameter = 3-Inches (75 mm)
Drive Head Outside Diameter = 4-Inchs (100 mm)
Screen Dimensions = 24-Inches L x 1.5-Inch OD x 50 Mesh
Screen Open Surface Area = about 25%
Core Dimensions = 2.5-Inch OD x 17 L
Water Canister Volume = 2 Liters
Water Canisters Can Be Stacked
Sample Discharge = Drain From Bottom after removed from core barrel section.
Pressurization = Typically Nitrogen gas or with air compressor (Top Connection = NW)
Application = Depth discrete groundwater profiling or depth discrete soil gas profiling.
Rig Compatibility = Hollow Stem Auger, Air Rotary Casing Hammer (ARCH),
Dual Wall Percussion (Becker Rig), Mud or Air Rotary.
Durability = Can be used with heavy pile driving equipment up to 10,000 Lb. strike load.
H2-Vape Probe (PDF Downloads)
Written SOPs (212k)
Vacuum Box SOPs (128k)
Illustrated SOPs (676k)
   
   
Click here to learn about MaxiProbe and MinProbe
MaxiProbes: Soil&Soilgas, Water Sampling Probe MiniProbe: Soil & Soil Gas